가스장비사업
원격검침용 스마트
계량기 사업
MAP 포장사업
LAB Gas System
Gas Safety System
압력제어
(Pressure Control)
유량제어
(Flow Control)
가스혼합
(Gas Mixing)
가스분석
(Gas Analysis)
가스안전
(Gas Safety)
특수사양 레귤레이터
(Special Spec Regulators)
가스발생
(Gas Generator)
원격검침
(Advanced Metering Infrastructure)
가스치환포장(MAP)
MAP 시스템 개요
가스혼합기
(Gas Mixer)
가스분석기
(Gas Analyser)
누설검지기
(Leak Detector)
적용분야
Q&A
자료실
실험실 가스공급
(Gas Supply)
실험실 가스분석
(Gas Analysis)
실험실 가스유량제어
(Gas Flow Control)
실험실 가스혼합
(Gas Mixing)
실험실 가스안전
(Gas Safety)
견적문의 전화상담요청 A/S 문의 기술자료 Case Study 자주묻는질문(FAQ) Trouble shooting
회사개요 인사말 회사연혁 조직도 최근소식/업데이트 품질/환경 경영방침 지적재산권/인증서 주요고객사 채용정보 연구개발 찾아오시는 길
|
Ordering
Information
MG50 -100 -200 ME and ME EX (fluctuating outlet) |
Specify when ordering |
|||
2 - 3
gases |
all
technical gases (excluding toxic, aggressive gases) |
Gas 1 |
Gas 2 |
Gas 3 |
Mixing
range |
0 - 25 %
or 0 - 100 % |
% |
% |
% |
Inlet
pressures |
between 4
and 20 bar max. |
bar |
bar |
bar |
Receiver
pressure |
max. 10
bar |
*default
seeting is PvDü,
if GB is
desired, please specify |
||
Integrated
inlet pressure
monitoring |
only
alarm: PvDü
solenoid
valve closes at alarm: GB |
|
|
|
Options
for inlet pressure
monitoring |
horn and
1 potential-free contact are integrated, to be
selected:
alarm lamp and/or another potential-free contact |
|
|
|
Analysis
(optional) |
e.g. GC
50 or PA 7.0 (below) |
|
|
|
Receiver
with installed
mixer
(optional) |
Steel
(St) or Stainless Steel (VA):
Volume:
100 l / 10 bar for MG50, 250 l /11 bar for MG100,
larger
receivers for MG200 from 500 l on are delivered only
separately,
because only available in vertical design |
|
|
|
Voltage |
230V AC,
110V AC or 24V DC or not electrical, than MP
version |
|
|
|
Mixture
outlet |
see table
on data sheet, max.: 161 Nm³/h |
Nm³/h |
Analysis GC 50 integrated in gas
mixer |
Specify when ordering |
|||
For 1 or
2 gases, mixer types: KM-ME, MG-ME |
CO2:
infrared
O2:
paramagnetic
O2:
electrochemical
O2: Zirconium
cell
H2:
thermal conductivity
He:
thermal conductivity
CH4:
infrared |
Gas 1 |
Gas 2 |
type of sensor
for O2 |
Range of
analysis |
O2: 0-100
%
CO2: 0-30
%, 0-100%
H2: 0-10
%, 0-30%, 0-100%
He: 0-30
%, 0-100%
CH4: 0-10
%, 0-100 % |
% |
% |
type of mixer |
Options
for integrated
analysis |
LED alarm
light, horn |
|
||
|
fully
automatic calibration |
Gas 1 |
Gas 2 |
|
|
Ethernet
connection to mixer on back. Standard: Ethernet
connection
to GC50 without cable lead through |
|
||
|
USB
interface to mixer on back or front.
Standard:
USB interface to GC50 without cable lead through |
|
||
|
data
logger |
|
||
|
digital
data recorder |
|
||
|
mail
service (transfer of occurred errors) |
|
||
|
Webvisio
for remote transmission of the settings and measurement results |
|